![]() |
| FM 200 Fire Suppression System in Bangladesh |
FM 200 Fire Suppression System Activation Procedure
Here's a general activation procedure for an FM200 fire suppression system. Please note that this is a general guide and you should always refer to the specific operation and maintenance manual for your installed system, as procedures can vary.
Assess the Situation: Confirm there is an actual fire and not a false alarm. Look for visible flames, smoke, or heat. Evacuate Personnel: Ensure all personnel in the protected area are safely evacuated. Initiate Building Alarm: Activate the general fire alarm for the building to alert other occupants. Notify Emergency Services: Contact the fire department or your internal emergency response team.
FM200 systems are typically designed to activate automatically through a fire detection system (e.g., smoke detectors, heat detectors). Upon detection, a pre-alarm warning will usually sound, allowing time for evacuation. After a set delay, the FM200 agent will be discharged.
Locate the Manual Release Station: This is usually a clearly marked pull station or button located at exits or within the protected area, and sometimes at a central control panel. It often looks like a "break glass" unit or a push-button. Activate the Manual Release: Pull Stations: Firmly pull down the lever. Push Buttons: Press the button until it latches or activates. Break Glass Units: Break the glass to access and activate the switch inside.
Verify Activation (If possible and safe): Look for indicator lights on the control panel or listen for the sound of the agent discharging (a loud whooshing sound).
Do Not Re-enter: Do not re-enter the protected area until it has been declared safe by trained personnel (e.g., fire department, safety officer). Ventilation: Ensure proper ventilation procedures are followed to remove any residual agent and combustion byproducts. FM200 is generally considered safe for occupied spaces, but good ventilation is always recommended after a discharge. System Reset and Recharge: The system will need to be inspected, reset, and recharged by a qualified fire suppression technician before it can provide protection again.
Training: All personnel who might need to operate the system should be properly trained. Signage: Ensure all warning signs, escape route signs, and manual release instructions are clearly visible and unobstructed. System Integrity: Regularly inspect and maintain the system according to manufacturer guidelines and local regulations. Breathing Apparatus: While FM200 is safe at design concentrations, in a real fire scenario, the products of combustion can be extremely dangerous. Always prioritize evacuation and never rely solely on the suppression agent for personal safety in a fire.
FM200 System Components
Here are the key components of an FM-200 fire suppression system:
FM-200 Agent Storage Cylinders: These are high-pressure cylinders that store the FM-200 (Heptafluoropropane) extinguishing agent in a liquid state. They are typically equipped with a valve assembly. Actuation System: This initiates the discharge of the FM-200 agent. It can be: Automatic Detection: Smoke or heat detectors sense a fire and send a signal to the control panel. Manual Release: A manual pull station allows for human activation. Solenoid/Pneumatic Actuator: An electrical solenoid or pneumatic device opens the cylinder valve when triggered by the control panel.
Nozzles: These are specially designed discharge devices that are strategically placed within the protected area. They rapidly convert the liquid FM-200 into a gas, ensuring even distribution and quick suppression. Piping Network: A system of pipes connects the FM-200 cylinders to the discharge nozzles, safely transporting the agent throughout the protected space. Control Panel: This is the "brain" of the system. It receives signals from detectors, monitors system status, activates the release mechanism, and often provides alarms and shutdown commands for ventilation or power. Detection Devices: As mentioned, these typically include smoke detectors (ionization or photoelectric) and/or heat detectors, designed to quickly identify the presence of a fire. Warning Devices: Audible Alarms: Sirens or horns to alert occupants. Visual Alarms: Strobe lights, especially important for noisy environments or for those with hearing impairments.
Pressure Switches: These devices monitor the pressure within the cylinders and piping, signaling any drop that might indicate a leak or discharge. Abort Switch (Optional but Recommended): A momentary switch that, when pressed, can halt the discharge sequence if activated during the pre-discharge delay, preventing accidental release. Manual Hold-Off Switch (Optional): Similar to an abort switch, but it can temporarily disable the automatic release sequence for a set period, useful during maintenance or when welding is being performed in the area.
The reliability of an FM-200 fire suppression system, when properly designed, installed, and maintained, is considered to be
Tested and Approved Standards: FM-200 systems are designed and installed according to stringent international standards such as NFPA 2001 (Standard on Clean Agent Fire Extinguishing Systems) and ISO 14520 (Gaseous fire-extinguishing systems - Physical properties and system design). Compliance with these standards ensures a high level of performance and safety.Rapid Detection and Response: Early Warning: Coupled with sensitive smoke and/or heat detection systems, FM-200 can detect a fire in its incipient stages, often before it fully develops.Fast Discharge: The agent discharges and suppresses the fire within 10 seconds, significantly limiting damage compared to slower-acting systems.
No Residue: As a clean agent, it leaves no residue, eliminating the risk of damage or downtime associated with cleanup, which can be critical for business continuity. This inherent characteristic enhances its "reliability" in terms of post-fire recovery.Minimal Collateral Damage: It is non-conductive and non-corrosive, meaning it won't damage sensitive electronic equipment, documents, or artwork. This makes it highly reliable for protecting valuable assets that are susceptible to damage from water or other extinguishing agents.Robust Components: The system components (cylinders, valves, piping, nozzles, control panels) are engineered for durability and long-term performance.Regular Maintenance is Key: While inherently reliable, the ongoing reliability of any fire suppression system, including FM-200, is heavily dependent onregular inspection, testing, and maintenance (ITM) . This includes:Annual inspections: Checking agent quantity, pressure, and all components.Functional tests: Testing detection devices, control panel, and alarm systems.Prompt repair of any deficiencies. Proper certification: Ensuring the system is installed and maintained by qualified professionals.
Single Point of Failure (Mitigated): While the system relies on a sequence of events (detection, control panel activation, agent discharge), each stage is designed with reliability in mind. For instance, detection systems often use cross-zoning (two detectors in alarm) to prevent false discharges.
Improper Design: Incorrect agent quantity, nozzle placement, or pipe sizing can compromise effectiveness. This is mitigated by requiring design by certified professionals following strict standards.Poor Installation: Faulty wiring, leaky pipe connections, or incorrect component installation. Mitigated by using qualified and experienced installers.Lack of Maintenance: Can lead to undetected leaks, pressure loss, or malfunctioning components. Mitigated by strict adherence to ITM schedules.Room Integrity: The protected space must be relatively airtight for the FM-200 to reach and maintain its effective concentration. Gaps or unsealed openings can lead to agent leakage, reducing its effectiveness. Room integrity tests are performed to ensure this.


No comments:
Post a Comment
WAZIPOINT:
Thank you very much to visit and valuable comments on this blog post. Keep in touch for next and new article. Share your friends and well-wisher, share your idea to worldwide.