WAZIPOINT Engineering Science & Technology

Thursday, July 30, 2026

SURGE ARRESTERS SPECIFICATION FOR 132 KV & 33 KV LINE

Surge Arrester Or Lightning Arrester Specification
Surge Arrester Specification

Surge Arrester Requirements for 132kV and 33kV Underground Cable Line Projects

 
Surge arresters shall be of the type employing non-linear metal oxide resistors without spark gaps. The Contractor shall demonstrate by calculations that the surge arresters will adequately protect the switchgear arrangement proposed.

Friday, July 24, 2026

Distribution Transformer Noise Diagnosis


The Most Dangerous Noises in a Low-Voltage Distribution Transformer (And What Each One Means). A field engineer's guide to diagnosing distribution transformer noise — buzzing, crackling, popping, and hissing sounds explained against IEC 60076-10, IEEE C57.12.90, and BNBC 2020, with a risk-based response matrix. Distribution transformer noise diagnosis, transformer buzzing sound causes, transformer partial discharge sound, IEC 60076-10 noise limits, transformer core saturation noise, Buchholz relay gas alarm, transformer overheating sound, dangerous transformer sounds, distribution transformer maintenance Bangladesh.

Distribution Transformer Noise Diagnosis


Wednesday, July 22, 2026

How to read Transformer Nameplate?

Transformer Nameplate: WAZIPOINT

The Practicing Engineer's Guide to Ratings, Vector Groups, BIL, and Cooling Codes A field-ready guide to interpreting power transformer nameplates — cooling codes, %Z, BIL, vector groups, tap ranges, and hot-spot limits — mapped to IEC 60076-1:2011 and IEEE C57.12.00-2021, with worked calculations and Bangladesh/PGCB procurement context. Focus Keyword: how to read a transformer nameplate Secondary Keywords: transformer nameplate data, transformer cooling class ONAN ONAF OFAF, transformer vector group Dyn11, basic insulation level BIL transformer, transformer percentage impedance short circuit calculation, IEEE C57.12.00-2021, IEC 60076-1:2011 Slug: how-to-read-transformer-nameplate-guide Category: Power Systems & Substation Engineering

How to Read a Transformer Nameplate: Ratings, Vector Groups, BIL, and Cooling Codes Decoded

Tuesday, July 21, 2026

Future of Renewable Energy in Bangladesh




The Future of Renewable Energy in Bangladesh: A 2041 Roadmap for Solar, Wind, Hydro, and Biomass Meta Description: Bangladesh's renewable energy roadmap to 2041 — solar rooftop policy, offshore wind in the Bay of Bengal, cross-border hydro imports, biomass, BESS, and the engineering path to a 20% renewable grid.

Monday, July 20, 2026

Wazipoint Motor Engineering


Motor Engineering — Post Archive | WAZIPOINT
WAZIPOINT · Engineering Science & Technology

Motor Engineering 

Label: Motor-Engineering
Source: wazipoint.com/search/label/Motor-Engineering
01 / 07

Saturday, July 18, 2026

Technical Specification of RMU- Ring Mains Units for Distribution Switchgears

Ring Main Unit

The RMU or Ring Main Unit is a factory-assembled, metal-enclosed set of switchgear used at the load connection points of a ring-type distribution network in an electrical power distribution system.