WAZIPOINT Engineering Science & Technology: HVAC ENGINEERING DICTIONARY

Monday, January 16, 2023

HVAC ENGINEERING DICTIONARY

Sometimes it becomes difficult to describe the known terms clearly to others. This article is for the guy who works with HVAC, the terms related to the HVAC systems that every day you use, keep saved, and may need at necessary.

HVAC (heating, ventilation, and air conditioning) is a major sub-discipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort.

heating, ventilation (or ventilating), and air conditioning: The right HVAC system can help regulate the environmental factors inside your home, like air quality, humidity, and temperature.

Scroll Compressor Internal View
ABSOLUTE HUMIDITY - The weight of water vapor in a given amount of air.

ABSOLUTE PRESSURE - Pressure measured with the base of zero.

ABSOLUTE TEMPERATURE - A temperature scale expressed in degrees oF or oC using absolute zero as a base. Referred to as the Rankin or Kelvin scale.

ABSOLUTE ZERO - The temperature at which molecular activity theoretically ceases. -456.69 F0 or -273.16 oC.

AIR CONDITIONING - The process of controlling the temperature, humidity, cleanliness, and distribution of the air.
AIR, Standard Conditions - Conditions at which capacity ratings for air conditioning equipment are rated.

AMBIENT - Refers to the temperature surrounding a body or unit under test.

ATMOSPHERIC PRESSURE - The weight of a 1-unit column of the earth's atmosphere.

BIMETAL - Two metals with different rates of expansion fastened together. When heated or cooled they will warp and can be made to open or close a switch or valve.

BOILING POINT - The temperature at which the addition of any heat will begin a change of state from a liquid to a vapor.

Split, hybrid heat split, and ductless mini-split heating are three of the most common types of HVAC systems to choose from for your Homewood

BRITISH THERMAL UNIT (BTU) - The amount of heat necessary to change the temperature of 1 pound of pure water to 1 degree Fahrenheit (oF).

CAPILLARY TUBE - A refrigerant control consisting of a small diameter tube that controls flow by restriction. They are carefully sized by inside diameter and length for each particular application.

CENTIGRADE - A temperature scale with the freezing point of water at 0 C and the boiling point at 100 C at sea level.

CHECK VALVE - A valve designed to permit flow in one direction only.
COMPRESSION - The reduction of the volume of a vapor or gas by mechanical means.

Sponsored:

COMPRESSION RATIO - The ratio is determined by dividing the discharge pressure, in PSI (Pa), by the suction pressure in PSI (Pa).

COMPRESSOR - A mechanical device used to compress gases. Three main types - are reciprocating, centrifugal, and rotary.

CONDENSATION POINT - The temperature at which the removal of any heat will begin a change of state from a vapor to a liquid.

Each type of HVAC system falls into one of two categories: ducted or ductless

CONDENSING MEDIUM - The substance, usually air or water, to which the heat in a condenser is transferred.

CONDENSING UNIT - The portion of a refrigeration system where the compression and condensation of refrigerant are accomplished. Sometimes referred to as the 'high side'.

CONDUCTION - The transfer of heat from molecule to molecule within a substance.

CONTACTOR - An electromagnetic actuated relay. Usually used to refer to the relay which closes the circuit to a compressor.

CONVECTION - The transfer of heat by a moving fluid.

COOLING ANTICIPATOR - A resistance heater (usually not adjustable) in parallel with the cooling circuit. It is 'on' when the current is 'off", adding heat to shorten the off cycle.

COP- Ratio of work performed or accomplished as compared to the energy used.

CUBIC FEET PER MINUTE - A common means of assigning quantitative values to volumes of air in transit, usually abbreviated CFM.

CYCLE - The complete course of operation of a refrigerant back to a selected starting point in a system.
DENSITY - Mass or weight per unit of volume.

Ambient temperatures with a T1 class range from -7°C to +43°C, T2 from -7°C to +35°C, and T3 from -7°C to +52°C.

DISCHARGE LINE - A tube used to convey the compressed refrigerant vapor from the compressor to the condenser inlet.

DISCHARGE PRESSURE - The pressure read at the compressor outlet. Also called head pressure or high-side pressure.

DRY AIR - Air that contains no moisture vapor.

DRY BULB TEMPERATURE - Temperature read with an ordinary thermometer.

EFFECTIVE TEMPERATURE - An arbitrary concept that combines into a single value the effect of temperature, humidity, and air movement as sensed by the human body.

ENTHALPY - Total amount of heat in one pound (kg) of a substance calculated from the accepted temperature base, expressed in BTU's per pound mass (J/kg).

EQUIVALENT LENGTH - That length of straight tubing that has the same pressure drop as the fitting, valve, or accessory (of the same nominal size) is considered.

EVAPORATIVE COOLING - The cooling effect of the vaporization of a liquid in a moving air stream.
EVAPORATOR - A device in which a liquid refrigerant is vaporized. Some superheating usually takes place.

EVAPORATOR SUPERHEAT - The actual temperature of the refrigerant vapor at the evaporator exit as compared to the saturated vapor temperature indicated by the suction pressure.

EXTERNAL STATIC PRESSURE - The sum of the static and velocity pressures of a moving air system at the point of measurement.

FAHRENHEIT - A temperature scale with a freezing point of water 320F and a boiling point 2120 F at sea level.

FEET PER MINUTE - A term assigned to a velocity of a moving air stream, usually express FPM.

FILTER-DRIER - A device that removes moisture, acid, and foreign matter from the refrigerant.

There are two main types of air handling unit — the 'blow-through' and the 'draw-through'.

FLASH GAS - Instantaneous evaporation of some liquid refrigerant at the metering device due to pressure drop which cools the remaining liquid refrigerant to desired evaporation temperature.

FREEZING POINT - The temperature at which the removal of any heat will begin a change of state from a liquid to a solid.

GAUGE PRESSURE - Pressure measured with atmospheric pressure as a base.

HEAT - A form of energy causing the agitation of molecules within a substance.

HEAT EXCHANGER - A device for the transfer of heat energy from the source to the conveying medium.

HEAT FLOW - Heat flows from a warmer to a cooler substance. The rate depends upon the temperature difference, the area exposed, and the type of material.

HEAT OF COMPRESSION - The heat added to a vapor by the work done on it during compression.

HEAT OF THE LIQUID - The increase in total heat (Enthalpy) per pound of a saturated liquid as its temperature is increased above a chosen base temperature. (Usually - 400F for refrigerants).

HEAT TRANSFER - The three methods of heat transfer are conduction, convection, and radiation.
INCHES OF MERCURY - Atmospheric pressure is equal to 29.92 inches of mercury.

LATENT HEAT - Heat that produces a change of state without a change in temperature; i.e., ice to water at 32 oF or water to steam at 212oF.

LATENT HEAT OF CONDENSATION - The amount of heat energy in BTUs that must be removed to change the state of one pound of vapor to one pound of liquid at the same temperature.

L1 and L2 represent the two poles on an AC power supply. L1 and L2 provide power to the components on the line side of the circuit.

LATENT HEAT OF FUSION - The amount of heat energy, in BTUs required to change the state of one pound of a liquid to one pound of a solid at the same temperature.

LATENT HEAT OF MELTING - The amount of heat energy, in BTU, that must be removed to change the state of one pound of solid to one pound of vapor at the same temperature.

LATENT HEAT OF VAPORIZATION - The amount of heat energy in BTUs required to change the state of one pound of a liquid to one pound of vapor at the same temperature.

LIFT - To elevate a fluid from one level to a higher level.

LIQUID LINE - A tube used to convey the liquid refrigerant from the condenser outlet to the refrigerant control device of the evaporator.

MANOMETER - A tube filled with a liquid used to measure pressures.
MBH - One MBH is equivalent to 1,000 BTUs per hour.

MEAN TEMPERATURE DIFFERENCES - The mean of the difference between the temperature of a fluid receiving and a fluid yielding heat.

MELTING POINT - The temperature at which the addition of any heat will begin a change of state from a solid to a liquid.

MERCURY MANOMETER - Used to measure vacuum in inches of mercury.

MICRON - A unit used to measure high vacuums. One micron equals 1/25,400 of one-inch mercury.
MOLLIER CHART - A psychrometric chart. How to convert between Mollier and Psychrometric charts?

MUFFLER - Device installed in the hot gas line to silence discharge surges.

OIL SEPARATOR - A device for separating out oil entrained in the discharge gas from the compressor and returning it to the crankcase.

PARTIAL PRESSURE - The pressure exerted by any individual gas in a mixture.

PITCH - The slope of a pipeline for the purpose of improving drainage.

PITOT TUBE - A device comprising a small diameter orifice projecting directly into an air stream measuring total pressure and surrounded by an annular section with small diameter entrances normally to the flow, measuring static pressure; both sections are usually connected to a manometer to indicate velocity pressure.

PRECHARGED LINES - Refrigerant lines which are filled with refrigerant and are sealed at both ends. The seals are broken when the lines are installed and the line charge becomes part of the total system charge.

PRESSURE DROP - The decrease in pressure due to friction of a fluid or vapor as it passes through a tube or duct or/and lift.

PRESSURE - TEMPERATURE RELATIONSHIP - The change effected in temperature when pressure is changed or vice versa. Only used in saturated conditions. An increase in pressure results in a temperature increase. A decrease in temperature results in a pressure decrease.

PUMP DOWN - Process of pumping refrigerant out of the evaporator and suction line at the end of the on-cycle by closing a solenoid valve in the liquid line and letting the compressor shut off by the low-pressure control.

PSYCHROMETER - A device having both a dry and wet bulb thermometer. It is used to determine the relative humidity in a conditioned space. Most have an indexed scale to allow direct conversion from the temperature readings to the percentage of relative humidity.

PSYCHROMETRIC CHART - A chart on which can be found the properties of air under varying conditions of temperature, water vapor content, volume, etc.

QUICK CONNECT - Name given to the end connections on precharged lines which screw onto mated fittings of the outdoor and indoor sections. Tightening the quick connections ruptures the seals on the fittings and the line charge becomes part of the total system charge.

RADIATION - The transfer of heat without an intervening medium. It is absorbed on contact with a solid surface.

RECEIVER - A vessel for holding refrigerant liquefied by the condenser.

REFRIGERANT - A substance that produces a refrigerating effect while expanding or vaporizing.

REFRIGERANT CONTROL - A device used to meter the amount of refrigerant in an evaporator. It also serves as a dividing point between the high and low-pressure sides of the system.

REFRIGERANT DISTRIBUTOR - A device that meters equal quantities of refrigerant to independent circuits in the evaporator coil.

REFRIGERANT MIGRATION - The movement of refrigerant through the system to the compressor crankcase during the off-cycle, caused by its attraction to oil.

REFRIGERANT OPERATING CHARGE - The total amount of refrigerant required by a system for correct operation.

REFRIGERANT VELOCITY - The rate at which refrigerant is moving at a given point in a system, usually given in feet per minute (FPM).

REFRIGERATION - The transfer of heat from a place where it is not wanted to a place where its presence is not desirable.

REFRIGERATION EFFECT - The amount of heat a given quantity of refrigerant will absorb in changing from a liquid to a vapor at a given evaporating pressure.
RELATIVE HUMIDITY - The percentage of water vapor present in a given quantity of air compared to the amount it can hold at its temperature.

RELAY - A device used to open and close an electrical circuit. The relay may be actuated by a bimetal electrically heated strip, a rod wrapped with a fine resistance wire causing expansion when energized, bellows actuated by the expansion of a fluid or gas, or an electromagnetic coil.

REVERSING VALVE - A device in a heat pump that is electrically controlled to reverse the flow of refrigerant as the system is switched from cooling to heating; also called a four-way valve.

RISER - A vertical tube or pipe which carries refrigerant in any form from a lower to a higher level.
SATURATED VAPOR - Vapor in contact with a liquid.

SATURATION - A condition of stable equilibrium of a vapor and a liquid.

SENSIBLE HEAT - Heat that can be measured or felt. Sensible heat always causes a temperature rise.

SIGHT GLASS - A glass installed in the liquid line permitting visual inspection of the liquid refrigerant for the purpose of detecting vapor in the liquid. They also generally have a device included to monitor the moisture content of the refrigerant.

SLUGGING - A condition in which a quantity of liquid enters the compressor causing hammering and possible compressor damage.

SPECIFIC HEAT - The amount of heat necessary to change the temperature of one pound of a substance 10 F.

SPECIFIC VOLUME - The volume of a substance per unit of mass; i.e., standard air is 13.33 cubic feet per pound. The reciprocal of density.

STANDARD AIR DENSITY - .075 pounds per cubic foot. Equivalent to dry air at 700 F and at sea level pressure.

STATE CONDITION - Substances can exist in three states - solid, liquid, or vapor.

STATIC PRESSURE - The normal force per unit area at a small hole in the wall of a duct.

STATIC TAP - A means by which static pressures of a duct system may be read directly, usually consisting of a small diameter hole in the side of the duct connected to a manometer.

SUB COOLING - Cooling of a liquid, at a constant pressure, below the point at which it was condensed.

SUBLIMATION - A condition where a substance changes from a solid to a gas without becoming a liquid.

SUCTION LINE - A tube is used to convey the refrigerant vapor from the evaporator outlet to the suction inlet of the compressor.

SUCTION LINE ACCUMULATOR - A device located in the suction line that intercepts quantities of a liquid refrigerant and thereby prevents damage to the compressor.

SUPERHEAT - Heat added to vapor after all liquid has been vaporized.

TEMPERATURE - A measurement of heat intensity.

THERMISTOR - Basically a semiconductor that has an electrical resistance that varies inversely with temperature.

THERMOSTAT - A bimetal actuated switch to close and open a circuit to indicate or terminate the operation of a heating or air conditioning system.

THERMOSTATIC EXPANSION VALVE - Refrigerant control which monitors the flow rate according to the superheat at the evaporator outlet.

TON OF REFRIGERATION - The amount of heat necessary to completely melt one ton of 32oF ice in 24 hours.

Sponsored:

TOTAL HEAT (Enthalpy) - Total heat energy in a substance. The sum of sensible and latent heat.

TOTAL PRESSURE - The sum of all partial pressures in a mixture of gases.

TRAP - A depression or dip in refrigerant piping in which oil will collect. A trap may be placed at the base of a suction or hot gas riser to improve oil return up the riser.

VACUUM - Any pressure below atmospheric pressure.

VAPOR BARRIER - The term applied to an impervious layer of material superimposed upon a layer of insulation. Vapor barriers are always applied on the warm side of the insulation layer.

VAPOR PRESSURE - The pressure exerted by vapor.

VELOCITY PRESSURE - In a moving fluid, the pressure capable of causing an equivalent velocity is applied to move the same fluid through an orifice such that all pressure energy expanded is converted into kinetic energy.

WATER MANOMETER - Used to measure pressure in inches of water.
WET BULB TEMPERATURE - Temperature read with a thermometer whose bulb is encased in a wetted wick.

3 comments:

  1. I am always searching online for articles that can help me. There is obviously a lot to know about this. I think you made some good points in Features also. Very helpful information, thank you! Chris Johnson

    ReplyDelete
  2. One of the main problems with air conditioners is dirt and, as such, it's important to ensure yours is clean. Simply turn off power to the air conditioner, and using your garden hose, try to remove as much dirt, seeds, leaves and debris as you possibly can. Do this on a regular basis especially during the cooling season. Emergency AC Repair Toronto

    ReplyDelete
  3. Wow, this is good post, I have also seen this information here, car parts in mansfield
    Very nice post car stereo shops near me

    ReplyDelete

WAZIPOINT:
Thank you very much to visit and valuable comments on this blog post. Keep in touch for next and new article. Share your friends and well-wisher, share your idea to worldwide.

You may like the following pages